Hematology Analyzers (Blood Cell Counters) and Blood Grouping Instruments - Reviewed

Blood samples are subjected to testing using hematology analyzers. They are employed in the medical industry to perform coagulation tests, complete blood counts, reticulocyte analyses, and white blood cell counts. Hematology analyzers are available for both human and animal blood, which is helpful for research labs, zoos, and veterinarians. Hematology analyzers have different features, such as closed vial testing and open sampling testing. Several hematological analyzers give the customer the option of selecting their preferred testing method. 

Additional characteristics of a hematology analyzer to take into account include the necessary sample size, the kind and number of testing modes, the speed at which results are available, the automated flagging of findings that are outside of the normal range, and the number of test results it can hold.


1. SMART-II Auto Hematology Analyzer Blood Cell Counter 29 Parameters

Profit from thorough and precise analysis in your low-volume lab environment. The SMART-II hematology analyzer can assist you in making more effective and timely clinical decisions. The SMART-II, which is based on tried-and-true cellular analysis technology, offers precise platelet counts and reliable first-pass readings. As a result, you may cut back on expensive test replays and laborious manual reviews. The system's user-friendly design also makes it simpler to understand and use, freeing up your employees to concentrate on providing patient care.

Hematology Analyzer

Features

5-part blood cell counter

25 parameters +3 histogram+1 3D scattergram

2 test mode

60 samples/hour 

14'' large touch screen

External USB printer

Support LIS system
Stable, durable and economical

Performance

1. High Stability & Accuracy

Advanced Sweep-Flow technology guarantees low PLT samples counted precisely.
Combined with optical and impedance method to make the BASO measurement more reliable and stable
Creative SMART-FLOW fluidic technology to makes SMART-II with good reliability and free of maintenance.
 

2. User-friendly System

1. 14 inch touch screen with high resolution and sensitivity, can be operated by wearing gloves
2. ONE touch to start the test,
3. ONE click to remove error,
4. ONE screen for most of the daily operation.
 5. Intelligent turn off power switch.

3. Cost-effective and Attractive Design

Low running cost, only three reagents needed for the test ,
Low reagent consumption for single test.
Low volume sample consumption
CBC+DIFF mode:≤20ul, CBC mode:≤10ul, ideal choice for pediatrics and geriatrics.

Hematology Analyzer Blood Cell Counter

Technical Specifications

Principle 

Tri-angle Laser scatter
3D Scattergram analysis
Flow Cytometry method
Cyanide free reagent for HGB test
Impedance method for RBC and PLT counting
 

Parameters   

25 Reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#
1 3D Scattergram
3 Histograms(WBC/BASO, RBC,  PLT)
4 Research parameter: ALY%,  ALY#,  IG%,  IG#
 

Throughput: 60 samples per hour

Test Mode: 
CBC mode, CBC+DIFF mode
Venous whole blood, Capillary whole blood and Prediluted

Sample Volume:    
CBC+DIFF mode: ≤20ul
CBC mode: ≤10ul

Display: 14 inch touch screen, resolution 1366*76

Storage:  Up to 100,000 results(including histogram, scarttergram, patient information

Printout: Support various external USB printers, printout formats user definable

Communication: Bi-direction LIS, support HL7 protocol Internal RFID reader

Interface:1 LAN port, 4 USB ports

Working Conditions: Temperature:10-30℃
Humidity: 20% - 85%
Air pressure: 70~106kPa
Working latitude: ≤3500m
Power supply:AC100-240v,50/60HZ

Dimension:  480x375x517mm(L*W*H)
Weight: 36Kg(net)



Hematology Analyzer


2. SY-B006 5 Diff Blood Corpuscle Analyzer Auto Blood Chemistry Analyzer

The SY-B006 5 Hematology Analyzer offers time and resource savings, eliminates manual intervention, and produces high-quality results even for patient groups with challenging draw.


Blood Corpuscle Analyzer

Technical Specifications


Parameters: 

27 parameters: WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU#, EOS#, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, RETIC%,  RETIC_ABS, IRF

2 Histograms for RBC and PLT
2 Scatter grams: 5-part differential scatter gram

Eosinophils and Neutrophils scatter gram
2 3-D stereograms


Principles of operation:

WBC 5-part:Flow Cytometry(FCM)+ 4 angles laser light scatter

WBC Analysis: Optical and impedance measurements

RBC/PLT Analysis: Impedance method

HGB test: Cyanide-free reagent colorimetry

RET test: Flow Cytometry(FCM)+laser light scatter+Chemical dye method


Sampling modes: Auto loader 160uL·Manual mode 160uL,Pre-diluted mode 40ul

Aperture Diameter: WBC 100um·RBC/PLT 80um

blood-corpuscle-analyzer

Throughput: Auto loader up to 110 samples per hour
Manual mode up to 100 samples per hour

Sampling device: Automatic sampling device with a capacity of 120 samples,
10 samples×12 racks, auto built-in barcode reader

Display: PC display with Linux system,14 inch color TFT display

Dimension: 760MM×684MM×676.5MM

 ·Laser light multi-dimensional cell classification
 ·Double mode for WBC counting (Impedance Count and Optical Count)
 ·Resistant RBC mode
 ·Sample rotatory valve quantification technique
 ·Up to 110 samples per hour
 ·Walk-away automation, high efficiency and accuracy
 ·WBC 5 part diff with sheath reagent only


Blood Corpuscle Analyzer


3. Automatic Blood Grouping Instrument PLS-MY-B006K

Using procedures like ABO grouping, Rh typing, antibody screening, and cross matching, an automated blood grouping machine can identify a person's blood type. The presence or absence of the two antigens A and B allows for the division of blood grouping systems into four categories. Testing for blood groups can be done manually or automatically using instrumentation systems. Red cells are initially immobilized onto a solid support medium made of polystyrene for the Solid Phase Red Cell Adherence Assay (SPRCA). The foundation of erythromagnetic technology is the utilization of paramagnetic particles that have been adsorbed on RBC surfaces. For blood type prior to a blood transfusion or for donor screening, automated blood grouping devices are mostly employed in hospital blood banks and  blood transfusion/donor centers for blood typing prior to a blood transfusion or when classifying a person’s blood for donation.

Automatic-Blood-Grouping-Instrument



For Micro-gel Blood Grouping Test 

Test application

ABO / RhD blood group detection (forward ), ABO / RhD blood grouping test (reverse)), RhD blood grouping antigen test (RhD genotyping), anti-human globulin test (cross matching), anti-human globulin test (irregular antibodies), anti-human globulin classification test  (IgG / C3d allergy) test; 

Image collection and results analysis automatically; 
*Test Speed: 80 tests / hour; 
*customizing incubation time, centrifugation speed and centrifugation time on request; 
*Reagents &sample:Support bar code scanning and location identification; 
*Bilateral LIS, support, manual / automatic result acquisition ,; 
*Flexible and customized printing function

Features

1. MODEL on table

2. Outline Dimension 1320(L)X870(W)X965(L)

3. Weight 260KG

4. Inspection Speed Up to 80 tests/Hour

5. Reagent Area 12 reagent, shake well

6. The sample area 96 samples, continuous loading, bar code scanning, support a variety of mainstream code system, can be loaded in succession

7. Cleaning port To clean the double needle

8. Disinfection area Two bottles, is used to disinfect double needle (not required)

9. Diluent area Two bottles, is used to dilute of red blood cells

10. Blending area 96 - well plates, used to dilute samples of red blood cells

11. Incubate area Can incubate 24 reagent card at the same time

12. Reagent card rack area 60 reagent card storage, can be loaded in succession

13. Pierce area Complete the prick reagent card automatically

14. The centrifuge One centrifuge. 24 reagent screens; Automatic centrifugal

15. Robot One; Automatic scratch card, Pierce, barcode scanning

16. Sampling needle Double needle with liquid level detection sensor, automatic detection samples, diluent, reagent level

17. The user software Windows xp/Windows 7 operating system, in both Chinese and English operation interface, abnormal information identification, tips, man-machine dialogue, reagent project added at any time, to use to.



Automatic-Blood-Grouping-Instrument


4. Mayamed Medical Equipment Lab Automatic Blood Test Machine Auto Hematology Analyzer PLS-MY-B003

The PLS-MY-B003 Hematology Analyzer uses patented VCS technology to provide precise findings for the initial analysis. Its sophisticated analyzer optimizes operations to maximize laboratory staff time with fewer slide checks and strong system dependability for optimal uptime. The analyzer can be combined with automation and clinical informatics programs to create scalable, unique solutions.

Medical-Equipment

Features

Flexible and Easy To Use
Fully automatic analysis cycle.
Automatic internal and external probe cleaning)
High Reliability and Safety
Total Solution For QC and Calibration
Comprehensive QC programs including L-J , auto draw and print QC graph
Automatic and manual calibration
Unique calibration program with fresh blood
Customizable software is available
Huge storage of 30,000 patient with histogram
Easy to check the patience data
Programmable multi-format printout

Specification

Test principle

Electrical resistance for counting and Cyanide free method for HGB

Clot clear

High voltage burn and high pressure flush

Sample volume

whole blood : 9.8μl, prediluted : 20μl

Aperture diameter

WBC: 100μ m, RBC,PLT: 70μ m

Chambers

Two chambers

Throughput

60 samples/hour

Language

English, Spanish, French, and Chinese

Reference range type

newborn, children, male, female and general

Display

10.4 inch color touch screen, show all parameters and histograms

Input and output

USB, keyboard, mouse, Parallel Port,RS232 serial port, can be connected to the network by external computer.

Working Environment

Temperature:10℃~35℃;Humidity:≤85% RH

Voltage

AC 110 V~240V,50Hz/60 Hz±1Hz ,Auto adapt according to the input voltage

Dimension

370mm×435mm×472mm

Net weight

30Kg


Parameter

Parameter

Linearity

Precision(CV%)

WBC(109/L)

0.3~99.9

2.5(7.0~15.0)

RBC(102/L)

0.20~8.0

2(3.5~6.0)

HGB(g/L)

10~250

1.5(110~180)

MCV(FL)

0.5(80.0~110.0)

PLT(109/L)

10~99.9

5(150~500)

Carry over

WBC≤0.5%     RBC≤0.5%     HGB≤0.5%      PLT≤1%




Auto-Hematology-Analyzer

5. Medical Laboratory Blood Coagulate Machine Full Automatic Coagulation Analyzer PLS-MY-B032C

The blood coagulation analyzer uses optical colorimetry as its detecting method. After the reagent and plasma are combined, fibrinogen is changed into fibrin and coagulated, which changes the test specimen's optical density and allows the device to detect the end point of coagulation.

Application:

Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), and fibrinogen (FIB) can all be detected with this method in plasma.
extensively used in blood labs, biochemical labs, hospital blood labs, and other labs.

Technical Parameters

*Test Method: optical method, magnetic beads method
*Test Item: APTT, TT, PT, FIB and blood coagulation factors, coagulation-related special items e.g. D-dimer and FDP
*Test Speed: 260Ts/h
*Sample Site: 48
*Reagent Site:55
*Pre-heating Site:20
*Probe: 2
*Washing Site: 2
*Sheathed Manipulator: 1
*Automatic and manual dual-mode test capability
*Insufficient cuvette and reagent alarm function
*Tilt reagent position(extend the use time of reagent to avoid waste and ensure the accuracy of the test results)
*Reagent position with refrigeration function
*Sampling probe with liquid surface induction and constant heating function
*Display coagulation curve of dynamic test
*PT-derived FIB function
*Automatic or manual calibration function
*LED work lighting function
*Batch test and emergency priority insertion test function
*Abnormal test results alarm and automatic retest function
*Insufficient test results alarm and waste liquid overflow alarm function
*Bar code recognition function(optional)
*Sheathed manipulator definitely avoids the risk of cuvette to be fallen off in the transposition process through gripping
*Four directions ventilation and cooling function, makes it reliable operation
*Infinite storage for test and quality control data
*Cuvette loading capacity: 1000 cups
*Any sample position has the function of emergency priority inserting
*Drawer-style loading system
*Immediate scanning transmission, then enter patient information soon
*Waste container, reduces pollution









Post a Comment

0 Comments